Abstract

In an experiment on a cadaver, a potential difference was rhythmically impressed upon two small electrodes thrust into the heart or its immediate neighborhood. The resulting differences in potential between a central terminal and four electrodes connected to it through equal resistances were recorded with the string galvanometer. The four electrodes were on the two arms, the left leg, and the left interscapular region. By assuming that the electrical field generated in the trunk was equivalent to that of a centric doublet in a homogeneous spherical conductor and that the four electrodes were at the apices of a tetrahedron inscribed in this sphere, the experimental and the theoretical amplitudes of the deflections in the four leads could be compared. In general, it may be said that, with one exception, the deflections in the limb leads had the relative magnitudes expected. The deflections in the lead from the back were much smaller than anticipated. The last result is attributed to circumstances peculiar to the single experiment performed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.