Abstract

Currently, the pollution control situation of the sewage systems across Taiwan can be divided into the two major sewage systems, namely, industrial area sewage and public community sewage. When the counties and cities of Taiwan cannot effectively control the sewage pollution situation, ecological pollution of the environment and personal health damage would result. Therefore, evaluating the pollution control situation of the sewage systems can help the environmental protection authorities developing strategies for the pollution control of the sewage systems in the future. In this study, the Vise Kriterijumska Optimizacija I Kompromisno Resenje (VIKOR) method was applied to evaluate the pollution control situation of the sewage systems. The water sample test qualification rate, the emission permit issuance rate, and the staff setting rate of the dedicated wastewater treatment company were used as the pollution control evaluation indexes. According to the results, the use of the VIKOR method to evaluate the pollution control situation of the sewage systems is effective. In cities and counties in Taiwan, public community sewage systems, dedicated to pollution control case, the public community should be actively coached in emission control technology to upgrade sewage capacity, the issuance of discharge permits, and the staff setting rate of the dedicated wastewater treatment, to improve public community sewage pollution control system capabilities. In Taiwan, the industrial area sewage systems, dedicated to pollution control situations, must pay attention to business units in raw materials, spare part inventory, and machine supplier of choice, and we must choose to meet environmental supply chain of green suppliers, which would be effective in reducing effluent produce and improve water sample test qualification rate. The VIKOR value of Yilan County is 1.0000, which is the worst in the pollution control of all the industrial area sewage systems, followed by Taoyuan County (0.2253) and Kaohsiung City (0.1334). Other cities and counties of Taiwan have good performance in the pollution control of the industrial area sewage systems. The VIKOR value of Kinmen County is 1.0000, which is the worst pollution control among the all public community sewage systems, followed by Hsinchu County (0.7458) and New Taipei City (0.5527). Among the cities and counties with good pollution control of the public community sewage systems, the best is Chiayi County (0.0000), followed by Kaohsiung City (0.0159) and Hsinchu City (0.0352). Chiayi County is a good performance compromise between all VIKOR values (0.0000), whether in industrial or public community area pollution control sewage systems. Yilan County industrial pollution control has the poorest performance of all the industrial area sewage systems in Taiwan, but in the public community, it ranked as fourth place of all the public community area sewage systems in Taiwan. The VIKOR method proposed in this study can effectively evaluate the pollution control situation of the sewage systems, and serve as a reference for the environmental protection authorities in developing the strategies for the pollution control of the sewage systems.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.