Abstract
Through using dual Fourier transform quantitative analysis and harmonic loss calculation on the output voltage of three phase voltage-Sinusoidal Pulse Width Modulation (SPWM) inverter, a valid harmonic inhibition scheme is presented. Carrier frequency is reasonably selected to eliminate low times harmonics, harmonics of carrier frequency times and triple frequency sideband. Analysis of fast Fourier transform is achieved in MATLAB. Simulation results show that harmonics are effectively inhibited, output voltage waveform is improved and voltage distortion factor is decreased from1.16% to 0.71%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.