Abstract
In this study, the sewage sludge dryer is installed before and after dehydration of the sludge and aqueous phase composition, the heavy metal content, and measurement and analysis were investigated. The removal efficiency of water content of sewage sludge was about 95.7% in the sewage sludge dryer. The removal efficiency of water content for primary dryer was designed for 35% of primary drying, secondary drying to remove the water content to 10%, but as the measurement revealed that 20.8% of primary drying, the second dryer 3.3% a better effect to the actual operation respectively. Before the installation of the sewage sludge dryer, the content of heavy metal was as follows, Cu:352~614 ppm, Hg: 1.3~1.44ppm, Cd : 1.1~1.86ppm, Pb : 17.25~ 28.93 ppm, As : 1ppm. And after the installation of the sewage sludge dryer, the content of heavy metal changed to as follows, Cu : 340~350 ppm, Hg : 0 ppm, Cd : 0~0.021 ppm, Pb : 0 ppm, As : 0~0.043 ppm which is Also below the legal limits. Also, the sewage sludge dryer produce 1/4 of the sewage sludge into dried sludge.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.