Abstract
The section of steel column under axial compression presents heterogeneous material and its load condition changes after experiencing fire damage of one side. Taking H-section steel column under axial compression commonly used in engineering for study object in this thesis in order to study post-fire residual load bearing capacity, the post-fire eccentric effect of steel column under axial compression exposure to one-side fire is analyzed using the method of equivalent section which considering the change of the material strength after high temperature, the influence of non-uniform temperature field on material properties and the stiffness degradation of member section. Calculation methods of the eccentricity and additional moment are proposed and further given a formula of residual load bearing capacity.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.