Abstract

For the efficient application of vanadium redox flow battery (VRB) in microgrid containing the clean renewable energy and advanced coal-fired power system such as the supercritical carbon dioxide (S-CO2) Brayton cycle power plant, a feasible energy filtering optimization process is proposed in this paper. A coupled dynamic response model of VRB and an optimized load distribution algorithm are covered in the process. First, the Ustack-Ibattery-SOC curves are fitted based on the coupled calculation model of VRB. The equivalent resistance of the simplified equivalent circuit model is further calculated. The dynamic response model is refined for the fast calculation of real-time efficiencies. Second, a basic operation scheme and an optimized operation scheme based on the moving average filtering method are selected as the load distribution algorithms. An energy filtering optimization management process that includes a configuration optimization design part and a load distribution part is further constructed. Finally, a case application is carried out to verify the feasibility of the proposed energy management process. The relevant results are presented as follows. First, the combination of the experimental data and the fitted curves can be used to calculate the equivalent resistance of the dynamic response model. The maximum Ustack of 86.14 V is obtained at the SOC of 0.99 and Ibattery of 10A when charging. Second, when applying the optimized operation scheme, the time average efficiency of VRB is operating at an efficient level of 82.75%. The change frequency of load command for each equipment and its dynamic response characteristic can be well matched. Finally, compared to the case where the basic operation scheme is selected in the experimental system, the time average efficiency of VRB is increased from 69.50% to 82.13%., the time average efficiency of S-CO2 power plant is increased from 39.79% to 40.02%. The application of energy filtering optimization management process for the actual microgrid is feasible. The study can provide the operation scheme and case application for VRB energy storage system in the actual microgrid.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.