Abstract
A method for measuring adhesion between the glass shell and the metallic nucleus of an amorphous microwire was developed. It was revealed that the stress of separation of the glass shell from the metallic nucleus (pull-off stress) can vary from hundreds of MPa to units of GPa. It was found that the adhesion value between the glass shell and the metallic nucleus is 270 MPa. It was found that the annealing of microwires below crystallization temperature can lead to a more than 2-fold increase in the adhesion. The effect of adhesion on the stress state and coercivity of microwires under tension was analyzed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.