Abstract The injection of choked gaseous jets into the still air is investigated experimentally motivated by many industrial applications including flares and burners. The objective is to study the effect of injection angle on the jet mixing with ambient air. The experimental methods consist of particle image velocimetry (PIV) using pulsed Nd:YAG lasers of a choked gas jet, seeded with aluminum oxide particles, injected into the still air, seeded with water fog. The computational methods consisted of 7.7 × 106 cells simulation using starccm+. The test conditions include injection angles of 0 deg, 15 deg, and 30 deg. The results including mean and fluctuating velocities and the flow vorticity are presented. The flow field is not symmetric along the injection axis due to the asymmetric triggering of expansion fans. Moreover, the numerical simulation reveals the complex interaction mechanism of the expansion fans and shockwaves within the injection port.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.