Abstract
Stress corrosion cracking tests on annealed 316 stainless steel in water containing 5 ppm Cl− and <5 ppb O2 at 300°C have been conducted at a strain rate of 1.8 × 10−6 s−1. The tests were performed in a low flow rate refreshed autoclave loop under potentiostatic control. Stress corrosion cracking of the steel in 300°C water occurred in two ranges of electrochemical potential; >100 mV and −200 to −450 mV (SHE). The mechanism of stress corrosion cracking in the two potential ranges was anodic dissolution controlled. Crack initiation in the potential range −200 to −450 mV resulted from the presence of a thick magnetite film. The initiation and propagation of stress corrosion cracks in these water conditions is discussed; it is concluded that the surface state of the material is important in determining whether stress corrosion cracks are formed during slow strain rate tests.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.