Abstract

The Toronto SPV bioprosthesis for aortic valve replacement has been prospectively evaluated in 100 patients, since March 1993. Intraoperative transoesophageal and postoperative transthoracic echocardiography were used to assess valve function. Follow-up was complete in 74 patients at 6 months and in 38 patients at 1 year. The average valve size implanted was 26.5 mm. Some 37 patients had additional coronary artery bypass grafting surgery. The hospital mortality rate was 4%. Non-structural valve dysfunction occurred in one patient and late endocarditis in another patient required operation. There were no other valve complications. None of the patients developed clinically relevant aortic valve incompetence during follow-up and there was a significant decrease in pressure gradients, increase in valve orifice areas and decrease in left ventricular hypertrophy. Copyright © 1996 The International Society for Cardiovascular Surgery.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.