Abstract

In order to evaluate the stable operation of high temperature superconducting (HTS) power cable, the calculation of AC loss on HTS power cable is important factor. Because AC loss has a big effect on many superconducting equipments, which are fabricated using the HTS tape. In general, AC loss of the HTS tape can be calculated by using voltage variations of the tape with respect to the external magnetic field when AC current applied to the tape. In case of HTS power cable carrying AC current, however, because the magnetic field distribution in the cable is very complicated, it is hard to compute AC loss of the HTS cable directly using above method. In this paper, the stability evaluation of the HTS power cable was performed by the following procedures. Firstly, the voltage variations of the HTS tape carrying AC current in the external magnetic field with different field angle were measured and the magnetic field distribution of HTS power cable with AC current was analyzed. Then, AC loss of the HTS power cable was calculated by using the results of both the measurement and the analysis. The stable operation of the HTS power cable was evaluated on the basis of AC loss of the cable.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call