Abstract

The rotary valve speed control, extremely affected by nonlinear dependence of rotary valve load torque on rotation angle, affects the generation of drilling fluid pressure PSK signal and its quality. Based on load torque calculation model, the load torque feed forward compensation is used in linearized correction of rotation speed control system to enable the motor voltage to vary according to the calculation model. Additionally, the calculation model is also used in compensating the influence of serious nonlinearity in rotary valve load torque on rotation speed control. By means of closed-loop proportional-integral-derivative (PID) control which is formed by negative feedback of speed and the PID parameter values determination rule which is created by attenuating control of transient component in step response of rotary valve speed, the rapid servo control of rotary valve speed is realized. Simulink Simulation indicates that the closed-loop speed control system of rotary valve is able to track the change of control voltage pulse quickly and strongly suppress the interference influences from flow measurement error and load torque calculation model deviation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.