Abstract

We investigated the influence of the relative phase of a temporally modulated annulus on the perceived flicker strength of a center stimulus having the same temporal modulation. These measurements were performed in two subjects at two temporal frequencies and with different outer diameters of the annulus. The perceived flicker strength was strongly modulated by the phase difference between center and surround stimulus. This modulation depended on the size of the annulus. In the absence of an annulus the perceived flicker strength was not modulated. The modulation initially increased with increasing annulus size and reached a plateau. The space constant of the function describing the modulation as a function of annulus size was about 0.5° and is similar to the sizes of receptive field surrounds of subcortical cells. This finding is in favor of the hypothesis that the physiological basis of the perceived flicker strength in the center stimulus is present already at a subcortical level.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.