Abstract
During the aqueous film coating of tablets, components of tablets tend to migrate to the film coating. This migration is enhanced if a component is soluble in the coating solution and also depends on the spray condition used during the coating operation. In this study, a 23 orthogonal factorial design was used to study the migration of drug and stearic acid from a tablet to an aqueous-based cellulose coating solution. The independent variables evaluated were atomization air pressure, inlet air temperature, and spray rate. Differential scanning calorimetry was used to quantitate the presence of guaifenesin and stearic acid in the film coating. In the 24″ Accela Cota that was used on our experiment, only spray rate and inlet air temperature influenced the migration of drug and stearic acid the film coating.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.