Abstract

A Monticelli-Spinelli small pin circular external fixator was used in combination with closed reduction or a limited open reduction internal fixation in five cases in an attempt to salvage a satisfactory result in distal tibia pilon fractures when associated soft tissue compromise prevented standard fixation with plates and screws. The small pin fixator enhances the ability to perform a closed reduction through a technique that uses distraction with pins in the tibia and calcaneus, combined with correction of angulation by tensioning wires with a stop nut. Small pin stabilization of these comminuted fractures allows early patient mobilization. The small diameter pins support the soft cancellous bone fragments. This technique attempts to combine the benefits of traction, external fixation, and limited internal fixation. We recommend this technique as a salvage procedure when plates and screws are contraindicated because of poor bone and soft tissue conditions.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.