Abstract
Oxygen bubbles are formed on the anode in the copper electrowinning process. Burst of the bubbles produces acid mist in the tankhouse. While it is well acknowledged that the amount of acid mist is related to the size of the bubble, no systematic measurements have been made to quantify bubble size and its relationship with materials and process variables. This paper presents results of bubble size measurement under different operating conditions. For each of the operating conditions tested, bubbles were detected in a wide size distribution ranging from 20 μm to more than 400 μm in diameter. Statistical analyses on the measurement results showed that addition of FC-1100, a surfactant widely used in copper electrowinning to suppress acid mist, and solution temperature were the two most influential test parameters on the bubble size followed by the age of the anode. In contrast, current density and solution acidity had negligible effect.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.