Abstract
In a Hall plate with finite size and contacts the Hall output voltage is given by the product of sheet resistance, input current, Hall mobility, magnetic flux density, and Hall geometry factor GH. GH∈[0,1] accounts for the loss in signal due to the contacts. At weak magnetic field GH→GH0 is a function of geometrical parameters only, which makes it the crucial point for layout optimization. We show how to express GH0 alternatively as a function of electrical parameters only, namely of input and output resistances over sheet resistance. This allows for an analytical optimization of signal-to-noise-ratio (SNR) without getting lost in the multitude of geometrical representations of equivalent Hall plates. In the course of this investigation we notice a hidden symmetry property of GH, which we prove rigorously in the limit of small magnetic fields. The physical meaning of this symmetry in the case of Hall plates with equal input and output resistances is also explained.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.