Abstract

The aim of this study was to assess whether a short breath-hold technique can improve hepatic arterial phase (HAP) image quality in gadoxetic acid-enhanced magnetic resonance (MR) imaging compared with a conventional long breath-hold technique. Institutional review board approval and patient consent were obtained for this prospective randomized control study. One hundred nineteen patients undergoing gadoxetic acid-enhanced MR imaging were randomly assigned to groups A or B. Group A patients underwent an 18-second long breath-hold MR technique (conventional VIBE [volumetric interpolated breath-hold examination] technique with GRAPPA [generalized autocalibrating partially parallel acquisition]), and group B patients underwent a 13-second short breath-hold MR technique (VIBE technique with CAIPIRINHA [controlled aliasing in parallel imaging results in higher acceleration]). Respiratory-related graphs of the precontrast and HAP were acquired. The breath-hold degree was graded based on the standard deviation (SD) value of respiratory waveforms. Gadoxetic acid-related dyspnea was defined as when the SD value of the HAP was 200 greater than that of the precontrast phase without degraded image quality in the portal and transitional phases (SD value of the HAP - SD value of the precontrast phase). The overall image quality and motion artifacts of the precontrast and HAP images were evaluated. The groups were compared using the Student t or Fisher exact test, as appropriate. The incidence of breath-holding difficulty (breath-hold grades 3 and 4) during the HAP was 43.6% (27/62) and 36.8% (21/57) for group A and B, respectively. The SD value during the precontrast phase and the SD value difference between the precontrast and HAP were both significantly higher in group A than in group B (P = 0.047 and P = 0.023, respectively). Gadoxetic acid-related dyspnea was seen in 19.4% (12/62) of group A and 7.0% (4/57) of group B. Group B showed better precontrast and HAP image quality than group A (P < 0.001). Degraded HAP (overall image quality ≥4) was observed in 9.7% (6/62) and 3.5% (2/57) of group A and B, respectively. The short breath-hold MR technique, CAIPIRINHA, showed better HAP image quality with less degraded HAP and a lower incidence of breath-hold difficulty and gadoxetic acid-related dyspnea than the conventional long breath-hold technique.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call