Abstract

In this study, a microbiological inhibition method for rapidly screening antibiotics in swine urine was established with an easy sample pre-treatment. The microbiological system consisted of an agar medium mixed with nutrients, sensitizers, a test bacterium (Geobacillus stearothermophilus ATCC12980) and pH indicator (bromocresol purple). It was observed that the detection limits of the test kit for twenty-eight common antimicrobial residues in urine, including β-lactams, aminoglycosides, tetracyclines, sulfonamides, macrolides, and lincosamides, were less than or equal to the maximum residue limits of the kidney, as determined by the EU and China. Moreover, the false negative rate and the false positive rate, along with other performance indexes such as interassay coefficients of variation and shelf life of the kit, all met the standard requirements of the ISO13969:2003 guidelines. Additionally, our results were consistent with those using the gold-standard physical chemistry method, which suggest the proposed method is suitable for screening antibiotic residues.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.