Abstract

Article deals with research problem of the methods of single defects search in continuous dynamical systems, of an automatic control class with a depth to dynamic block using vector of topological relations, based on integral estimates of signal deviations of model and object, with use of normalized diagnostic signs. This approach simplifies the implementation of the algorithm, especially in the diagnosis of non-linear objects. The use of topological relations of the matrix can reduce the hardware or software costs associated with the implementation of trial deviations of model parameters or functions of sensitivity and simplicity of the algorithm calculating the diagnostic signs. The results of the implementation of the algorithm, showing its effectiveness and to ensure high distinction of the defects.