Abstract

In order to evaluate the Scanning Laser Ophthalmoscope as a method of assessing diabetic retinopathy, 57 consecutive patients with diabetes were examined through undilated pupils using laser ophthalmoscopy followed by pupillary dilatation and direct ophthalmoscopy. Results of laser scanning were recorded on videotape and analysed independently. Scanning (both eyes) took under 5 minutes per patient. For the 113 eyes studied, the two techniques gave concordant results in 73/113 (65%). Where there was discordance, laser ophthalmoscopic severity was greater than direct ophthalmoscopy in 36/40 (90% of discordant results). In 4/40 eyes conventional ophthalmoscopic appearances were judged more severe than those seen with the laser. The laser ophthalmoscope may have value as a method of assessing diabetic retinopathy, but further work is required to evaluate its efficacy as a screening tool in patients with moderate to severe retinopathy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.