Abstract

A Roebel cable is a good candidate for low-voltage windings in a high-temperature superconductor (HTS) transformer because of its high current-carrying capability and low AC loss. Transport AC loss measurements were carried out in 1.8 m long 15/5 (fifteen 5 mm wide strands) and 15/4 Roebel cables. The results were compared with those in many Roebel cables composed of 2 mm wide Roebel strands. Comparison of the AC losses hinted that the intrinsic difference in normalized transport AC losses is due to differences in the g/w (ratio of the horizontal gap between the Roebel strands over the Roebel strand width) values. The intrinsic difference was confirmed by measuring transport AC loss in a series of horizontally arranged parallel conductor pairs with various g values. A method to scale transport AC losses in Roebel cables with varying strand parameters was developed. The scaling method will be useful for a rough assessment of AC loss in one-layer solenoid winding coils, such as in a HTS transformer.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call