Abstract

This study attempted to determine the safety of percutaneous release of trigger fingers, with particular attention given to border digits and the thumb. We performed percutaneous release of the A1 pulley in six fresh frozen cadaveric hands utilizing established surface landmarks. After freezing all specimens, we performed cross-sections at the A1 pulley, avoiding dissection of soft tissues, which could alter the natural position of the digital nerves. There was no difference in the distance from the needle tract to the neurovascular bundle when comparing between digits, and the closest distance was 2.7 mm. There was no significant difference between the needle tract and the radial and ulnar digital nerves. Based on our findings, percutaneous trigger finger release can safely be performed on all digits, including the thumb, small fingers, and index fingers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.