Abstract

Abstract: Currently, in Japan, the most commonly used embryo vitrification method is “ultra-rapid vitrification” which is designed to achieve the maximum cooling rate by exposing embryos directly to LN2 in a tiny droplet of cryoprotectant. Though this method has yielded acceptable embryo viability rates, questions have been raised by various countries' regulatory agencies regarding the effects of LN2 exposure. The 0.25 ml plastic straw has long been used as an entirely closed vitrification system. However, the cooling rate is slower using the 0.25 ml straw than when using the ultra-rapid cooling method, resulting in injury to embryos exposed to a high concentration of cryoprotectant. Recently, a new system has been developed which addresses both the issues of rates of cooling and safeguards against LN2. This paper compares the clinical results of blastocyst vitrification and warming using the conventional 0.25 ml straw method with those of the Rapid-i™ method. The survival rate after warming the group cry...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.