Abstract

BackgroundThe safety and efficacy of 17-gauge needles used in CT-guided percutaneous cryoablation for lung nodules were explored in this study. The purpose of the study was to compare the findings with earlier research and multi-center clinical trials that used various needle sizes.MethodsBetween 2016 and 2020, a retrospective study was conducted with approval from the institutional review board. A total of 41 patients were enrolled, and 71 lung nodules were treated in 63 cryoablation procedures using local anesthesia. Complication rates were recorded, and overall survival rates as well as tumor progression-free rates were calculated using the Kaplan-Meier method.ResultsSelf-limited hemoptysis was caused by 12.9% of the procedures, and drainage was required for pneumothoraces resulting from 11.3% of them. The overall survival rates at one, two, three, and four years were 97%, 94%, 82%, and 67%, respectively. The tumor progression-free rates at one, two, three, and four years were 86.2%, 77%, 74%, and 65%, respectively.ConclusionCryoablation for lung nodules using 17-Gauge needles can achieve similar rates of survival and tumor control rates, similar or even lower complication rates as compared with other studies and multi-center trials using mixed sized needles.