Abstract
AbstractThis paper contains results of experimental studies of the direct current breakdown voltage curves and volt‐ampere characteristics of discharges generated in a system consisting of two plane‐parallel tungsten and molybdenum electrodes at separations from 100 µ m to 1 µ m. The measurements were performed in the pressure range from 22.5 Torr to 738 Torr. The results are presented in the form of Paschen curves. Based on the measured breakdown voltage curves, the effective yields have been estimated in the case of different cathode materials. Differences between them are attributed to the influence of the work function of the cathode material on the current‐voltage characteristics due to field emission effect in small gaps and high pressures. At low‐pressures, however, vaporation of impurities from the electrodes material becomes significant. The present paper delivers new data on DC breakdown under these experimental conditions and conditions on the validity of the Paschen law in helium and provides better insight into the role of the field emission and the electrode materials on the breakdown voltage. (© 2013 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.