Abstract

As part of the energy transition in Germany, high-voltage overhead power lines will be operated using hybrid systems that combine alternating and direct current (AC and DC). The degree to which humans perceive hybrid electric fields (EFs) is dependent on the proportion of both EF types. To investigate the impact of the DC component, a study assessed 49 participants with above-average EF detection ability under conditions with a low DC component of 1–4 kilovolts per meter (kV/m) and varying AC EFs between 1 and 14 kV/m. The detection thresholds of combined AC/DC EFs decreased with an increase in the DC component and ranged from 9.6 to 6.83 kV/m on average for the group. The results suggest that even minor variations in the DC component significantly affect human perception of hybrid EFs. These findings complement the results of an earlier study that investigated the AC component in hybrid EFs. Correlational analyses of both studies demonstrated the reliability of participants' performance. This study contributes to our understanding of EF-related effects on human perception and can aid in the planning of energy transmission near areas where humans work or live.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.