Abstract

Objective To investigate the role of segmental bioelectrical impedance technique (SBIA) in the assessment of intraperitoneal ultrafiltration volume with peritoneal dialysis patients. Method We selected the patients at the Department of Nephrology of the First Affiliated Hospital of Zhengzhou University and measured the segmental bioelectrical impedance by a German Fresenius body composition analyzer (the Fresenius whole body composition measurement (BCM) machine was used as a segmental machine in this study). An alternating current (5 kHz, 0.05–0.7 mA) was continuously released during the measurement. The released current penetrated the peritoneal cavity on both sides of the body, from which the segmental resistance at a frequency of 5 kHz was obtained from the multifrequency data (R5/Ω). Baseline BIA measurements were initiated after the patient entered the supine position for 5–10 min, then dialysate was instilled into the peritoneal cavity. BIA measurements were performed at 10-min intervals during the retention of dialysate in the abdomen and finally ended when dialysate drainage was complete. Real-time intraperitoneal volume estimated by SBIA (IPVSBIA)and ultrafiltration volume estimated by SBIA(UFVSBIA) was calculated. At the same time, the actual ultrafiltration volume at the end of peritoneal dialysis was weighed and measured (UFVMEA). Results A total of 30 patients were included in the study, 9 patients withdrew from the study due to subjective factors during the measurement process, and 21 patients completed the study. The correlation coefficient R 2 of UFVSBIA and UFVMEA was 0.21 (p < 0.05). Bland-Altman analysis showed that the bias of UFVSBIA to the actual UFVMEA was 0.12 L, and the 95% agreement limit was between −0.5 L and 0.74 L, which confirmed that UFVSBIA measured by electrical impedance method and UFVMEA measured by weighing method were in good agreement. The time required to reach the maximum ultrafiltration volume (UFVSBIA) was 108 ± 68 min, and the mean value of the maximum ultrafiltration volume (Max UFVSBIA) was 1.16 ± 0.60 L. Conclusion The segmental bioelectrical impedance technique can be used to assess the intraperitoneal ultrafiltration volume of peritoneal dialysis patients in real-time and effectively. This method may guide the dialysis fluid retention time and the maximum ultrafiltration volume in PD patients.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call