Abstract

To evaluate the use of real-time shear wave elastography (SWE) in the assessment of renal elasticity and the efficacy of steroid treatment in adult idiopathic nephrotic syndrome (INS). This study included 120 patients with INS. Patients were divided into steroid-sensitive and steroid-resistant groups. Renal biopsy was performed. Thirty healthy subjects were recruited as controls. Young's modulus (YM) of the renal parenchyma was measured by SWE. The YM values in each group were compared using glomerular sclerosis index (GI) and renal interstitial fibrosis (RIF). The YM values were significantly different between the INS and control groups, as well as between the steroid-sensitive and steroid-resistant groups (P < 0.05). Higher YM values were associated with steroid sensitivity. The area under the receiver operating characteristic curve for the YM value in the INS group vs. control group was 0.871 (95% CI 0.815-0.927) and in the steroid-resistant group vs. control, and steroid-sensitive groups was 0.836 (95% CI 0.765-0.908). The corresponding cut-off values were 7.96 and 10.73m/s, with 81.7% and 86.0% sensitivities, 93.3% and 77.9% specificities, and Youden index 0.750 and 0.639, respectively. Spearman correlation analysis showed that the YM value in the renal parenchyma was positively correlated with GI (r = 0.631, P < 0.05) and RIF (r = 0.606, P < 0.05). SWE technology is a potential method for non-invasive quantitative measurement of renal parenchyma stiffness to determine the pathological changes of INS renal parenchyma and evaluate the effectiveness of steroid therapy.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call