Abstract

ObjectivesTo determine the incidence of abnormal radiological findings after cochlear implantation and their effect on clinical outcomes.MethodsRetrospective review of 220 adult cochlear implants. Clinical records and post-operative plain X-rays were reviewed and compared with pre-operative and 6-month post-operative City University of New York (CUNY) speech scores.ResultsThere were no cases of extra-cochlear array misplacement. Imaging showed 20 cases of incomplete array insertion (9.2%), 3 cases of kinking of the array (1.4%), 2 cases of tip rollover (0.9%), and 1 case of apparent array fracture (0.5%). Patient management was not altered by abnormal imaging. Patients with abnormal radiological findings had slightly minor improvements (median 39 vs. 56%) in City University of New York (CUNY) speech discrimination scores at 6 months (Mann–Whitney U test, P = 0.043).ConclusionAll abnormalities on post-operative imaging were minor and did not alter patient management. The future role of post-operative imaging is discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.