Abstract
Accurate treatment planning is recommended in peptide-receptor radionuclide therapy (PRRT) to minimize the toxicity to organs at risk while maximizing tumor cell sterilization. The aim of this study was to quantify the effect of different degrees of individualization on the prediction accuracy of individual therapeutic biodistributions in patients with neuroendocrine tumors (NETs). A recently developed physiologically based pharmacokinetic (PBPK) model was fitted to the biokinetic data of 15 patients with NETs after pre-therapeutic injection of (111)In-DTPAOC. Mathematical phantom patients (MPP) were defined using the assumed true (true MPP), mean (MPP 1A) and median (MPP 1B) parameter values of the patient group. Alterations of the degree of individualization were introduced to both mean and median patients by including patient-specific information as a priori knowledge: physical parameters and hematocrit (MPP 2A/2B). Successively, measurable individual biokinetic parameters were added: tumor volume V tu (MPP 3A/3B), glomerular filtration rate GFR (MPP 4A/4B), and tumor perfusion f tu (MPP 5A/5B). Furthermore, parameters of MPP 5A/5B and a simulated (68)Ga-DOTATATE PET measurement 60 min p.i. were used together with the population values used as Bayesian parameters (MPP 6A/6B). Therapeutic biodistributions were simulated assuming an infusion of (90)Y-DOTATATE (3.3 GBq) over 30 min to all MPPs. Time-integrated activity coefficients were predicted for all MPPs and compared to the true MPPs for each patient in tumor, kidneys, spleen, liver, remainder, and whole body to obtain the relative differences RD. The large RD values of MPP 1A [RDtumor = (625 ± 1266)%, RDkidneys = (11 ± 38)%], and MPP 1B [RDtumor = (197 ± 505)%, RDkidneys = (11 ± 39)%] demonstrate that individual treatment planning is needed due to large physiological differences between patients. Although addition of individual patient parameters reduced the deviations considerably [MPP 5A: RDtumor = (-2 ± 27)% and RDkidneys = (16 ± 43)%; MPP 5B: RDtumor = (2 ± 28)% and RDkidneys = (7 ± 40)%] errors were still large. For the kidneys, prediction accuracy was considerably improved by including the PET measurement [MPP 6A/MPP 6B: RDtumor = (-2 ± 22)% and RDkidneys = (-0.1 ± 0.5)%]. Individualized treatment planning is needed in the investigated patient group. The use of a PBPK model and the inclusion of patient specific data, e.g., weight, tumor volume, and glomerular filtration rate, do not suffice to predict the therapeutic biodistribution. Integrating all available a priori information in the PBPK model and using additionally PET data measured at one time point for tumor, kidneys, spleen, and liver could possibly be sufficient to perform an individualized treatment planning.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: European Journal of Nuclear Medicine and Molecular Imaging
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.