Several formulations of artificial saliva have been used for corrosion studies. The present work focuses on the effect of different saliva formulations on the composition of the surface film formed on CuZn37 brass alloy by X‐ray photoelectron spectroscopy (XPS), in order to clarify the corrosion mechanism of historical brass wind instruments when used. Three different saliva solutions, Darvell (D), Carter‐Brugirard (C‐B) and SALMO, were selected. They differ for the content of the organic compounds. The XPS results show the presence of a film made of CuSCN and zinc‐phosphate on the brass exposed to C‐B and SALMO. In the case of samples exposed to D formulation, phosphorus is not revealed, a decrease in the zinc content in the film is detected and the S 2p shows the presence of a second component together with the one ascribed to CuSCN. A comparison with the results obtained on the pure metals in the presence of the organic compounds suggests that the formation of zinc and copper complexes may lead to thin and less protective surface film and thus to the observed high corrosion rates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.