Abstract

Aims. We present a multi-frequency study of the ultraluminous infrared galaxy (ULIRG) IRAS 00183-7111 (z = 0.327), selected from the Spoon diagnostic diagram as a highly obscured active galactic nucleus (AGN) candidate. ALMA millimetre and X-ray observations are used; the main aim is to verify at what level the molecular gas, traced by the CO, may be responsible for the obscuration observed at X-ray energies. Theory and observations both suggest that galaxy-scale absorption may play a role in the AGN obscuration at intermediate (i.e. Compton-thin) column densities. Methods. We calibrated and analysed ALMA archival Cycle 0 data in two bands (Bands 3 and 6). The X-ray properties of IRAS 00183-7111 were studied by reducing and analysing separately archival Chandra and XMM-Newton data; recently acquired NuSTAR spectra were first examined individually and then added to the Chandra and XMM spectra for the broad-band (0.5 − 24 keV, observed frame) analysis. Results. We derived a molecular gas column density of (8.0 ± 0.9) × 1021 cm−2 from the ALMA CO(1−0) detection, while the best-fit column density of cold gas obtained from X-ray spectral fitting is 6.8−1.5+2.1×1022 cm−. The two quantities suggest that the molecular gas may contribute only a fraction of the AGN obscuration; however, the link between them is not straightforward. The nuclear regions of IRAS 00183-7111 are likely stratified into different layers of matter: one inner and highly ionized by the strong radiation field of the AGN (as inferred from the high-ionization iron line found in the X-ray spectra), and one outer and colder, extending more than 5 kpc from the nucleus (as traced by the molecular gas observed with ALMA). The molecular gas regions also give rise to a vigorous starburst with SFR ~260 ± 28 M⊙ yr−1. The complexity of this nuclear environment makes it difficult to identify the origin of the AGN obscuration given the quality of the data currently available. Higher resolution observations in the millimetre regime are needed to deeply investigate this issue.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.