Abstract
Atrioventricular (AV) junction ablation (AVJA) is an acceptable strategy to control the heart rate in atrial fibrillation (AF) with a high procedural success rate. However, a small subset of patients pose a technical challenge with the standard right-sided approach. High-output His-bundle pacing has been shown to help localize the His bundle in a difficult-to-ablate AV junction. We report a case series of patients with difficult-to-ablate AVJA and present strategies to troubleshoot them. In this small series of patients, we found that high-output His pacing can be an effective alternative for successfully localizing the AVJA site. In this series, we also observed that an inability to achieve His capture from the right side can predict failure of ablation using the standard right-sided approach and the consequent need for a left-sided approach.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of innovations in cardiac rhythm management
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.