Abstract

Friction has been widely used as a measure of slipperiness. However, controversies around friction measurements remain. The purposes of this paper are to summarize understanding about friction measurement related to slipperiness assessment of shoe and floor interface and to define test conditions based on biomechanical observations. In addition, friction mechanisms at shoe and floor interface on dry, liquid and solid contaminated, and on icy surfaces are discussed. It is concluded that static friction measurement, by the traditional use of a drag-type device, is only suitable for dry and clean surfaces, and dynamic and transition friction methods are needed to properly estimate the potential risk on contaminated surfaces. Furthermore, at least some of the conditions at the shoe/floor interface during actual slip accidents should be replicated as test conditions for friction measurements, such as sliding speed, contact pressure and normal force build-up rate.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.