Abstract
Internal fixation in proximal femoral osteotomies using traditional devices may be sub-optimal in children with neuromuscular disorders who have small or osteopenic bone. In this population, between 1988 and 2000, we performed 36 proximal femoral varus osteotomies in 28 patients. These were controlled by the AO external fixator. The average age at surgery was 7 years (range, 2-13 years). A mean varus correction of 34 degrees (range, 15-90 degrees) was obtained. Complications consisted of one superficial pin tract infection, one skin breakdown, and one non-union. Other than the non-union, all osteotomies were stable at the time of the fixator removal. The AO external fixator is an effective alternative in maintaining corrective proximal femoral osteotomies in children with fragile bones.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.