Abstract

A very simple analysis gives an upper bound to the restraining effect of the austenitic cladding on the stress intensity for the extension, at the deepest point, of a three-dimensional under-clad crack into the wall of a water-cooled nuclear reactor pressure vessel during a hypothetical overcooling accident. By comparing the upper bound results with results for a two-dimensional crack, it is concluded that cladding restraint is unlikely to provide a significant reduction in the stress intensity at the deepest point. This viewpoint is confirmed by additional results for a special case, namely that of a semi-circular under-clad crack.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.