Abstract

The response time of a rotor system supported upon a disk-type magnetorheological fluid damper operating on shear mode is measured experimentally. The effects of rotating speed, step current and magnetic particle volume fraction, on the response time are dealt with. It is shown that the dynamic response can be described by first 10% response time and rapid response time. Generally, the first 10% response time and the rapid response time are in order of less than 0.1 second and 0.1~0.4 second. The magnetic field strength, magnetic particle volume fraction and power supply have a great effect on the response time. The response time in dropping step current is several times longer than that in applying step current. There is a zero initial delay time at either applying or dropping the current, which is caused by the magnetizing or de-magnetizing process.