Abstract

An // neutral particle analyzer (NPA) has been designed and is under development at Sichuan University and Southwestern Institute of Physics. The main purpose of the // NPA is to measure the distribution function of fast ions in the HL-2A/3 tokamak. The // NPA contains three main units, i.e. the stripping unit, the analyzing unit and the detection unit. A gas stripping chamber was adopted as the stripping unit. The results of the simulations and beam tests for the stripping chamber are presented. Parallel electric and magnetic fields provided by a NdFeB permanent magnet and two parallel electric plates were designed and constructed for the analyzing unit. The calibration of the magnetic and electric fields was performed using a 50 kV electron cyclotron resonance ion source (ECRIS) platform. The detection unit consists of 32 lutetium-yttrium oxyorthosilicate (LYSO) detector modules arranged in two rows. The response functions of , hydrogen ions ( , and ) and for a detector module were measured with Am, Cs and Eu sources together with the 50 kV ECRIS platform. The overall results indicate that the designed // NPA device is capable of measuring the intensity of neutral hydrogen and deuteron atoms with energy higher than 20 keV.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call