Use Gambit and Fluent to the servo valve armature component of squeak problem undertook CFD is analyzed, simulates the flow field distribution in internal circuit structure, found in the servo valve armature component whistle when fluid in the inner of the product, produced a marked a negative pressure zone, and in this context the armature assembly stress sharply change, causing the armature assembly vibration squeal, changing the internal structure of the product again CFD simulation, negative pressure area disappeared, the pressure change tends to be steady, the structure of the product was the actual through pressure liquid servo valve test, howling problem solved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.