Abstract
The paper analyzed voltage variation generation mechanism of DC high voltage divider advances high voltage divider variation measurement method---serial and parallel voltage double-method, verifies the establishment condition of series and parallel double-voltage method in theory, measures the voltage variation of DC high voltage divider through experiment, the measurement uncertainty is better than 10-6.