Abstract

Abstract Background Repolarization abnormalities have a central role on the diagnosis of ARVC according to recent HRS consensus document from 2019 stating that T wave inversion in the right precordial leads is a major criteria if it appears in V1-V3 or a minor criteria if it appears in only V1-V2. Purpose The aim of our study was to investigate whether repolarization patterns as recorded by a Body Surface Mapping (BSM) system consisting of a vest with 252 ECG leads, could differentiate ARVC patients and even gene carriers from normal individuals. Our hypothesis is that the method can potentially identify repolarization disturbances earlier or better than conventional 12-lead ECG. Method 12 definite ARVC patients, 20 healthy gene carriers and 8 family members who tested negative for the family mutation (controls) were included. All patients underwent 12-lead ECG, including right precordial leads (V4R) and BSM recordings. Repolarization (T-wave polarity and concordance with QRS complex vector) was analyzed qualitatively in all BSM recordings, the results of which were displayed on a color code map (fig.1). Results The mean age was 49.6, 43.6 and 38.8 years in ARVC patients, healthy gene carriers and controls, respectively. The number of males in the three groups were 8/12, 8/20 and 5/8, respectively. All 8 controls had similar repolarization patterns with negative and concordant T waves on the right back panel, and T waves that successively changed from negative concordant (green) to positive disconcordant (red) and finally positive concordant (blue) on the left front panel (pattern 1). All 12 ARVC patients had different repolarization patterns as compared to the controls. Two of these patients had no apparent repolarization changes on conventional 12 lead ECG. The pattern type 2 repolarization, as defined by same pattern as the controls at the right back panel but different pattern at the front left panel was seen in 3/12 ARVC patients. The remaining 9 ARVC patients had different repolarization patterns both on the front and on the back panel (pattern 3). Among gene carriers, 15 had a normal repolarization pattern (pattern 1) and 5 demonstrated an abnormal repolarization pattern (4 had pattern type 2 and one pattern 3) despite normal surface ECG. Conclusions Using BSM recordings, abnormal repolarization patterns can be detected in all ARVC patients, even in those without repolarization changes on conventional surface ECG. The observation that 25% of gene carriers had divergent repolarization patterns, may indicate an early stage of the disease, and be used as an early diagnostic marker of the disease. Further and larger studies are warranted to confirm these observations. Repolarisation patterns recorded by BSM Funding Acknowledgement Type of funding source: Foundation. Main funding source(s): Selanders Stiftelse

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.