Abstract
The mercury (Hg) content of dental-operatory wastewater has become an issue in many localities, and Hg removal is rapidly becoming a matter of concern for all dental clinics. This preliminary study tested the efficacy of polymers for the removal of Hg contaminants from the dental-unit wastewater stream. Two commercially available polymers were used to treat dental-operatory wastewater. Used separately, each polymer removed from 74.9% to 88.4% of the Hg from dental-wastewater supernatant. The polymers used in combination, within the recommended pH range, removed up to 99.9% of the total Hg from dental-wastewater supernatant. The estimated optimal concentration of the two polymers is approximately 2.33 ml of each per liter of waste, and more than 90% of the Hg may be removed with 0.13 ml/l. Results indicate that a combination of the two polymers may sufficiently reduce Hg levels to allow discharge of clarified supernatants into public sewer systems.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.