Abstract

BackgroundForce plates are frequently used for postural control assessments but they are expensive and not widely available in most clinical settings. Increasingly, clinicians are using this technology to assess patients, however, the psychometric properties of these less sophisticated force plates is frequently unknown. The purposes of the study were to examine the test-retest reliability of a force plate commonly used by clinicians and to explore the effect of using the mean value from multiple repetitions on reliability.MethodsThirty healthy volunteer adults were recruited. Postural control measures were obtained using the Midot Posture Scale Analyzer (MPSA). Data were collected in 2 sessions. Five successive repetitions each of 60 seconds duration were obtained from each participant in each session.ResultsThe reliability coefficients obtained using single measures were low (ICC3,1 = 0.06 to 0.53). The average of two measures allowed for reliable measurements of COP mean velocity and average location of COP. The average of three and five measures was required to obtain acceptable reliability (ICC ≥ 0.70) of relative weight bearing on legs and sway area, respectively. Higher measurement precision values were seen by averaging four or five repetitions for all variables.ConclusionSingle measures did not provide reliable estimates of postural sway, and the averaging of multiple repetitions was necessary to achieve acceptable levels of measurement error. The number of repetitions required to achieve reliable data ranged from 2 to 5. Clinicians should be wary of using single measures derived from similar equipment when making decisions about patients.

Highlights

  • Postural control organises the orientation and equilibrium of the body during upright stance and is essential to the successful performance of daily movements and activities as well as fall prevention [1]

  • Standard deviations, reliability coefficients, standard error of measurement, minimal detectable difference (MDD), bias and Levels of agreement (LOA) statistics are presented in Table 1 for each dependant variable

  • Each of the five variables measured exhibited unacceptable levels of measurement error when calculated from single measures

Read more

Summary

Introduction

Postural control organises the orientation and equilibrium of the body during upright stance and is essential to the successful performance of daily movements and activities as well as fall prevention [1]. Postural control can be measured subjectively or objectively. Subjective measures of postural control are obtained through the use of questionnaires. Such questionnaires provide valuable information, they often have limitations with some special populations such as the elderly or individuals with specific physical or cognitive impairment [6,7]. Force plates are frequently used for postural control assessments but they are expensive and not widely available in most clinical settings. Clinicians are using this technology to assess patients, the psychometric properties of these less sophisticated force plates is frequently unknown. The purposes of the study were to examine the test-retest reliability of a force plate commonly used by clinicians and to explore the effect of using the mean value from multiple repetitions on reliability

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.