Abstract

BackgroundSublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitus and age. Despite many prevalence studies, it is still unclear how the reliability of SV inspection affects its predictive power. The aim of this study was to quantify the inspection reliability of SV.MethodsIn a diagnostic study, the clinical inspection of 78 patients by 23 clinicians was examined for the diagnosis of SV. Digital images of the underside of the tongue were taken from each patient. The physicians were then asked to rate them for the presence of sublingual varices (0/1) in an online inspection experiment. Statistical analysis for inter-item and inter-rater reliability was performed in a τ-equivalent measurement model with Cronbach's alpha and Fleiss κ.ResultsThe interrater reliability for sublingual varices was relatively low with κ = 0.397. The internal consistency of image findings for SV was relatively high with α≈ 0.937. This shows that although SV inspection is possible in principle, it has a low reliability R. This means that the inspection finding (0/1) of individual images often cannot be reproduced stably. Therefore, SV inspection is a difficult task of clinical investigation. The reliability R of SV inspection also limits the maximum linear correlation {r}_{max} of SV with an arbitrary other parameter Y. The reliability of SV inspection R = 0.847 limits the maximum correlation to {r}_{max} (SV, Y) = 0,920—a 100% correlation was a priori not achievable in our sample. To overcome the problem of low reliability in SV inspection, we propose the RA (relative area) score as a continuous classification system for SV, which normalises the area of visible sublingual veins to the square of the length of the tongue, providing a dimensionless measure of SV.ConclusionsThe reliability of the SV inspection is relatively low. This limits the maximum possible correlation of SV with other (clinical) parameters. SV inspection reliability is an important indicator for the quality of SV as a predictive marker. This should be taken into account when interpreting previous studies on SV and has implications for future studies. The RA score could help to objectify the SV examination and thus increase its reliability.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.