Abstract

The aim of this article is to research the characteristics of corrosion pit on 2xxx aluminum alloys in different environments (3.5wt% NaCl solution, water in fuel tank and wet air). Measure the area of corrosion pit, the depth of corrosion pit in different environments. The results show that in 3.5wt% NaCl solution: the initiation of surface corrosion pits mainly occur in 24h, with time increasing ,the depth of corrosion pit rises indistinctively; in water in fuel tank : during 24h-120h, with the extension of corrosion time, the maximum depth of corrosion pits changed a little, the maximum corrosion area became a little smaller than that in 3.5wt% NaCl solution; in wet air: the corrosion damage was smaller than that in 3.5wt% NaCl solution and water in fuel tank, the depth of the corrosion pit was about 20μm, the biggest size of corrosion pit area was about 0.5 x104μm2.