Abstract
The role of MICA antibodies in acute heart allograft rejection was examined utilizing 190 pre- and post-transplant serum samples from 44 patients collected during the first year after transplantation. MICA antibodies were detected by CDC test on recombinant cell lines and by the newly developed Luminex MICA antibody detection assay. Additionally, MICA expression was analyzed by 'real time' RT-PCR and by immunohistochemistry in 10 endomyocardial biopsies. Only two subjects had HLA antibodies post-transplant. Nevertheless, MICA antibodies were found in a significant number of subjects. The prevalence of MICA antibodies was significantly higher among those with severe acute rejection (AR) than in those without rejection (60.7% vs. 14.3%, p = 0.0038 by CDC; 55.5% vs. 5.7%, p = 0.0020 by Luminex). In most cases, the appearance of MICA antibodies post-transplant precedes AR. Following transplantation, MICA up-regulation correlated with histological evidence of severe rejection. Monitoring for MICA antibodies post-transplant may be useful to establish new risk factors for acute rejection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.