Abstract

We developed a system to adjust the rate of a continuous rocuronium (Rb) infusion to achieve 3 ≤ %T1 ≤ 10 with a closed-loop control. Samples were collected from 15 patients, and Rb blood concentrations were measured at the following time points: (1) when %T1 recovered to 3% or more after the initial Rb infusion; (2) when %T1 stabilized within the target range; (3) at the cessation of the Rb infusion; (4) 5 min after the sugammadex administration. The predicted Rb blood concentration at each time point was calculated and recorded using the pharmacokinetic parameters of Wierda et al. At time points (1), (2), and (3), the predicted blood concentrations were in good agreement with the measured values, but after the administration of sugammadex, the blood concentrations were higher than the predicted values because the Rb distributed in the tissues migrated into the blood. From the above, it was confirmed that the predicted blood concentration of Rb can be a good indicator for the automatic Rb administration control.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.