Abstract

Full-scale Monte Carlo simulations of the cyclotron room of the Buddhist Tzu Chi General Hospital were carried out to improve the inadequate maze design. The double differential neutron source from the 18O(p,n)18F reaction was adopted for the calculation. The weight window variance reduction technique, where the weight window was set by applying the adjoint flux, has been implemented in the MCNP run to facilitate the calculation of the dose rates outside the cyclotron room. Dose rates including neutron and gamma-ray components were calculated for some maze shielding modifications.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call