Abstract

BackgroundAlthough cardiac troponin T (cTnT) and troponin I(cTnI) are expressed to similar amount in cardiac tissue, cTnI often reach ten-times higher peak levels compared to cTnT in patients with myocardial necrosis such as in acute myocardial infarction (MI). In contrast, similar levels of cTnT and cTnI are observed in other situations such as stable atrial fibrillation and after strenuous exercise. ObjectiveExamine cTnT and cTnI levels in relation to COVID-19 disease and MI. MethodsClinical and laboratory data from the local hospital from an observational cohort study of 27 patients admitted with COVID-19 and 15 patients with myocardial infarction (MI) that were analyzed with paired cTnT and cTnI measurement during hospital care. ResultsLevels of cTnI were lower than cTnT in COVID-19 patients (TnI/TnT ratio 0.3, IQR: 0.1–0.6). In contrast, levels of cTnI were 11 times higher compared to cTnT in 15 patients with MI (TnI/TnT ratio 11, IQR: 7–14). The peak cTnI/cTnT ratio among the patients with MI following successful percutaneous intervention were 14 (TnI/TnT ratio 14, IQR: 12–23). The 5 COVID-19 patient samples collected under possible necrotic events had a cTnI/cTnT ratio of 5,5 (IQR: 1,9–8,3). ConclusionsIn patients with COVID-19, cTnT is often elevated to higher levels than cTnI in sharp contrast to patients with MI, indicating that the release of cardiac troponin has a different cause in COVID-19 patients.